LEO CNR4 Center Bay West Sensor Re-purposed

The west most CNR4 Sensor (LEO-C_10_-2_0_CNR4) was removed from the Center Bay mast on Thursday August 8th between 8am and 10 am by Aaron Bugaj.

This sensor is temporary being used in the West bay for a remote sensing experiment.

Jul 25 2019

LEO CSAT3

There is no LEO CSAT3 for the East or West bay installed due to damage/maintenance.

Data logging to the East and West bay have been stopped as of 7/25/2019 8:25am.

Jul 03 2019

Mar 14 2019

LI7000 missing data

LI7000 configuration was changed unknowingly, subsequently, we have a long time period of lost data.

Data since 2017-11-20 11:20:48.

The issue was rectified on 2019-03-13 22:23:05.

Oct 30 2018

PE102-038 East Bay -2 Swap

The PE102-038 in East bay -2 position was measuring about 1/2 of expected counts. Flowmeter from the +4 position in East bay was swapped with -2 position until a replacement is available. 

Oct 04 2018

10-4-2018 LEO Tipping bucket recalibration

We have recalibrated the LEO Novalynx tipping bucket. 10/4/2018 10:45pm data set onwards are using the new calibration values.

novalynx_calibration.png

6/4/2019: The following shows the updated calibration coefficients used on the Novalynx.

Novalynx_recalibrations.PNG

Sep 26 2018

Added UV sensor to LEO-OWS

A SU-100-SS-L-20 was added to the LEO-OWS.

*Found that 15 minute moving average for the HMP60, SQ110, LP02, was incorrect and has been fixed.
Unsure if 15 minute moving averaged data before 9/26/2018 12:15pm is correct.

Sep 06 2018

Irrigation and seepage flowrate changed to incremental

The volume calculations for the irrigation (EX81) and seepage (Novalynx,PE102) have been update to show the change in volume between each logging time period (15 minutes) instead of cumulative volume.

Data from 9/6/2018 1:45pm onward reflect these changes.

Expect some data interruption on 9/5/2018 and 9/6/2018.

**Fixed irrigation incremental logging on 9/11/2018 11:00am. Please disregard data recorded from 9/11/2018 8am to 11am.

***EX81 incremental liters/sec can also be found on the Labview DSM.

Mar 19 2018

Sep 11 2017

Tipping buckets LEO

Updated- 3/6/2019

West -1 NovaLynx tipping bucket was broken, Shell was replaced on 9/8/17. Calibration done and changed in DSM on server 9/11/17 12:45 to .033305 L/tip

East-2 NovaLynx tipping bucket was re-wired, possible bad connection creating spikes in data, will monitor over next rains and re-evaluate

1/15/19- Replaced reed switches on East Bay Nova Lynx +1 and +2 locations due to switch bouncing and noisy data. 


**The Nova Lynx proxy sensors have been rewired to eliminate the terminal block inside the tipping bucket enclosures. Rusting of the terminal blocks' terminals have been shorting the terminals causing noise. The voltage suppressor bi-directional diodes have been moved out of the rusting terminal blocks to the terminal blocks in the enclosure. Note that the terminal blocks were left inside the enclosures.

2/19/2019 - Rewired LEO East
3/6/2019 - Rewired LEO West. 3/13/2019 - LEO West leak tipping bucket

3/7/2019 - Rewired LEO Center bay